Leon Chun On Lee1, Sunny Chi Lik Au2*
1LKS Faculty of Medicine, University of Hong Kong, Hong Kong
2Department of Ophthalmology, Pamela Youde Nethersole Eastern Hospital, Tung Wah Eastern Hospital,
Hong Kong
*Corresponding Author: Sunny Chi Lik Au, Department of Ophthalmology, Pamela Youde Nethersole Eastern Hospital, Tung Wah Eastern Hospital, Hong Kong; Email: [email protected]
Published Date: 24-09-2021
Copyright© 2021 by Au SCL, et al. All rights reserved. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Abstract
Cosmetic industries are booming in many Asian cities where the uptake of laser treatment is becoming more frequent. The close proximity of the cosmetic laser handheld probe to the ocular adnexa is at risk of jeopardizing the retina. Cosmetic laser related eye injury was rare, and as an occupational hazard to the laser operating personnel was even rarer. Here, we present our opinion on reviewing reported cases in English literature. We aim to raise the awareness of cosmetic laser procedures’ devastating effect to the eye and subsequent ophthalmic management issues.
Keywords
Ophthalmology; Cosmetic Laser; Dermatology; Retina, Macula; Surgery; Vision; Eye
Introduction
Cosmetic industries are booming in many Asian cities where the uptake of laser treatment is becoming more frequent. Carbon dioxide, yttrium-aluminum-garnet and diode laser are commonly used in the aesthetic industry around the eyelids and periocular region for hair epilation, facial resurfacing and subcutaneous vein treatment [1-5]. With the vast expansion of laser indications in aesthetics, it carries harm to both clients and operators without strict compliance to proper safety protection and regulation [6,7]. The eyes are particularly vulnerable to laser injury through the thin eyelid skin and abundance of pigment-rich chromophores [8]. When laser is applied for cosmetics, the close proximity of the handheld probe to the ocular adnexa is at risk of jeopardizing the retina due to non-dispersed beam through the translucent cornea, lens and vitreous. Cases of cosmetic laser induced peripheral retinal injuries had been rarely reported (Chen, Shum, Kim) and all vision had recovered without intervention [9-11].
Discussion
We performed literature search in EMBASE, MEDLINE via OvidSP, PubMed, Google Scholar with terms cosmetic, eye, laser and injury and reviewed the reported cases. Cosmetic laser related eye injury were mostly case reports, with the beauty parlor clients being the victim most of the time. Cosmetic laser related eye injury was rare, and as an occupational hazard to the laser operating personnel was even rarer. Four case reports were found for cosmetic laser-induced retinal injury [9-12]. Their clinical histories and outcomes were summarized in Table 1. Three out of 4 patients had peripheral retinal injuries [9-11]. The initial symptoms were due to vitreous and retinal hemorrhage, and had remarkable recovery of vision without any surgical intervention [9-11]. There was one report of a 55-year-old patient with laser eye injury by a dermatologist complicated by secondary choroidal neovascularization later. It appeared that cosmetic laser eye injuries can rarely lead to devastating visual complications [13].
Among the commonly used carbon dioxide, yttrium-aluminum-garnet and diode laser [1]. Nd:YAG laser of 1064 nm is gaining popularity in Asia cosmetic industry due to its effect to deeper pigmentation and darker skin type [14,15]. Whereas Q-switch Nd:YAG is popular for its nanosecond duration that suits the short thermal relaxation time of melanosome in keeping the photothermal and photoacoustic effects limited to melanin only [16,17]. Asian usually is of Fitzpatrick’s skin photo type of IV to V and laser parameters in terms of spot size, duration, energy were all variable according to characteristics of the target [18,19].
However, the retina is particularly vulnerable to this Class 4 infrared range of retina hazard laser [20]. The wavelength of Nd:YAG 1064 nm laser makes it invisible to human eye and allows it to penetrate deeper into tissue compared to shorter wavelength of laser, making intraocular structures vulnerable to injury. In the cases reported by Chen, et al., Kim, et al., and Lee, et al., fibrosis occurred after retinal hemorrhage was absorbed, which resulted in scar formation and adhesions rather than progression into retinal detachment [9,11,12].
Increased risk of retinal detachment has been a speculated complication following Nd:YAG vitreolysis and Nd:YAG capsulotomy. The American Society of Retina Specialists (ASRS) Research and Safety in Therapeutics (ReST) Committee retrospectively reported 2 cases of retinal detachments and a case of retinal tear out of 15 complications following Nd:YAG vitreolysis in 2016-2017 [21]. Retinal detachment following Nd:YAG vitreolysis has been reported in 2 other retrospective case reviews [22,23]. Reported rates for retinal detachment after Nd:YAG capsulotomy was ranged between 0% to 4.8% [24,25]. The epidemiological evidence of retinal detachment associated with Nd:YAG capsulotomy and vitreolysis remains controversial due to the limited number of prospective clinical trials. A plausible mechanism is light emission damages the vitreous by oxidative stress, ionization, vaporization and cavitation leading to the loss of hyaluronic acid and liquefaction, and subsequently detachment of the posterior hyaloid causing RRD. Similarly, cosmetic Nd:YAG laser may lead to retinal detachment if inadvertently aimed to the eye. Cosmetic laser is mostly done in indoor settings where the eye is accommodating, with a short distance from the portable, handheld laser source. The cornea and lens help to focus the 1064 nm laser directly into the eye, thus, increasing the irradiance towards the vitreous and retina [26]. A number of factors may lead to predisposition to retinal detachment following cosmetic Nd:YAG laser injury to the peripheral retina, including long axial length myopia, high power laser and pseudophakic/aphakic eyes.
A histologic study by Manning, et al., demonstrated that Nd:YAG laser can lead to disruption of all retinal layers, a defect in Bruch membrane, and choroidal vessel rupture to cause subretinal hemorrhage, which may leak to the front of retina to form preretinal haemorrhage [13]. From the reported laboratory accidents, industrial and military experience, Nd:YAG 1064 nm laser is capable of causing retinal, sub-retinal or vitreous haemorrhage, with a similar clinical course of resorption of blood and subsequent scarring, macula hole and pre-retinal membrane formation [27-29]. We believed prompt surgical intervention was necessary to improve the visibility of retinal examination to achieve hemostasis, to identify the site of laser injury and to identify and treat any retinal breaks.
It is generally believed that the location of the retinal injury is the most important prognostic factor in determining the functional damage to the retina after laser eye injuries, publications reported good visual prognosis as most reported injuries were in the peripheral retina [30]. Reported laser eye injuries most frequently occurred during laser beam alignment or adjustment in experimental laboratories, industries and military [31]. The design of cosmetic laser apparatus is usually compact, handheld and portable, enhancing its uses in beauty parlors. Long wavelength Nd:YAG laser sources are more effective for pigmented Asian skin, however, it has high risk of penetration into deep intraocular tissues without protective media to the eye. Standard precaution as a safety measure for occupational health in terms of room design, authorization to facility usage and wavelength-specific safety goggles should follow the International Electrotechnical Commission (IEC) documents [32]. Protective eyewears should have permanent labels on the optical density for the wavelength covered, side shield protection, and intact surface [33]. Standardized regulation on laser machine operator’s proficiency training, registration and licensing, continuous renewal education are all suggested for legal authorization [34,35]. Legal claims from complications of cosmetic laser is not uncommon, yet legislation on regulation of aesthetic laser is not perfect [36,37].
| Chen 2014 [9] | Shum 2016 [10] | Kim 2019 [11] | Lee 2019 [12] |
Patient Demographics | 25 years old /Female | 31 years old /Female | 27 years old /Female | 55 years old /Male |
Occupation | Unknown | Aesthetician | Skin care technician | Dermatologist |
Laser Type | Nd:YAG 1064 nm | Nd:YAG 1064 nm | Nd:YAG 1064 nm | Nd:YAG 1064 nm |
Injury Mechanism | Unanticipated eye exposure during alig nment | Direct eye exposure with fixation on probe | Unanticipated eye exposure during alig nment | Reflection from reflective surface |
Eye Protection | Nil | Sunglasses | Nil | Nil |
Timing | Unknown | 1 day | 3 days | 2 weeks |
Presentation | Flashes, floaters | “Pop” sound, floaters, blurring of vision | Scotoma
| Central scotoma |
Presenting Visual Acuity | 20/20 | 6/30 | 20/20 | 4/32 |
Examination Findings | Inferior retinal burn with retinal edema around, vitreous haemorrhage | Well-demarcated semicircular patch of retinal edema nasal to optic disc, with overlying retinal haemorrhage of 2 DD and blood clot | Peripheral retina at 2 o’clock a 4 DD of subretinal haemorrhage with 2.5 DD of preretinal haemorrhage at center | Elevated intraretinal and subretinal haemorrhage of ¾ DD, Choroidal neovascularization |
Treatment | Oral prednisolone and vitamins (dosage not mentioned) | Observe | Oral steroids and vitamins (dosage not mentioned) | Intravitreal bevacizumab 1.25mg 3 times in 5 months |
Outcome | Defaulted follow-up | Scarred retina, residual dense scotoma | Scarred retina, residual scotoma | Not mentioned |
Nd:YAG: Neodymium-doped Yttrium-Aluminium-Garnet DD: Disc Diameters |
Table 1: Cosmetic laser-induced retinal injury cases summary.
Conclusion
The complication profiles following cosmetic laser eye injuries are poorly understood because these cases were scarcely reported and most had minor vitreous bleeding and good recovery without intervention. Our opinion article aims to raise the awareness of cosmetic laser procedures’ devastating effect to the eye and subsequent ophthalmic management issues. In case of inadvertent cosmetic laser eye injury, the victim must seek prompt ophthalmic consultation, for thorough eye check including a fundal exam. Initial floaters and vitreous hemorrhage may mask an underlying retinal detachment, therefore, patient must be followed-up frequently for early detection. Cosmetic laser procedures of the face have become more popular, and can cause eye injury to operator as severe as blindness without proper ocular protection. Training of operating personnel on laser safety eyewear is important on reducing this occupational hazard, and regulation on cosmetic laser usage out of medical area will prevent accidental eye injury leading to blindness.
References
- Preissig J, Hamilton K, Markus R. Current laser resurfacing technologies: a review that delves beneath the surface. Semin Plast Surg. 2012;26(3):109-16.
- Asiri MS, Alharbi M, Alkadi T, Abouammoh M, Al-Amry M, ALZahrani Y. Ocular injuries secondary to alexandrite laser-assisted hair removal. Can J Ophthalmol. 2017;52(2):e71-5.
- Newman JB, Lord JL, Ash K, McDaniel DH. Variable pulse erbium: YAG laser skin resurfacing of perioral rhytides and side‐by‐side comparison with carbon dioxide laser. Lasers in Surgery and Medicine: The Official J Am Society for Laser Med Surg. 2000;26(2):208-14.
- Goldman A, Lotti T, Tchernev G, Wollina U. Successful treatment of reticular blue veins of the lower eyelid by long-pulse nd: yag – case report with 8-year follow-up. Open Access Maced J Med Sci. 2017;6(1):58-60.
- Ashraf B. Nd: YAG 1064 nm laser in the treatment of periocular veins. J Egypt Women Dermatol Soc. 2013;10:5-9.
- Qutob SS, O’Brien M, Feder K, McNamee J, Guay M, Than J. Prevalence of laser beam exposure and associated injuries. Health Rep. 2019;30(1):3-9.
- Huang A, Phillips A, Adar T, Hui A. Ocular injury in cosmetic laser treatments of the face. J Clin Aesthet Dermatol. 2018;11(2):15-8.
- Sayed MS, Ko MJ, Ko AC, Lee WW. Ocular damage secondary to lights and lasers: How to avoid and treat if necessary. World J Ophthalmol. 2014;4(1):1-6.
- Chen SN, Lu CW, Hu X, Zhou DD. A case of accidental retinal injury by cosmetic laser. Eye (Lond). 2014;28(7):906-7.
- Shum JW, Iu LP, Cheung DN, Wong IY. A case of accidental ocular injury from cosmetic laser burn. Retin Cases Brief Rep. 2016;10(2):115-20.
- Kim RY, Ra H. Observation of changes after peripheral retinal injury by cosmetic laser, using wide-field scanning laser ophthalmoscope: A case report. Med (Baltimore). 2019;98(6):e14354.
- Lee YH, Kim YC. Foveal choroidal neovascularization secondary to accidental laser exposure in a dermatologist: A case report. Med (Baltimore). 2019;98(18):e15429.
- Manning JR, Davidorf FH, Keates RH, Strange AE. Neodymium: YAG laser lesion in the human retina: accidental/experimental. Contemp Ophthalmic Forum. 1986;4:86-91.
- Lipp M, Weiss E. Nonsurgical treatments for infraorbital rejuvenation: a review. Dermatol Surg. 2019;45(5):700-10.
- Chong LY. Laser therapy in dermatology: what have we learnt in the last decade? HK Pract. 2001;23:323-30.
- Xu TH, Yang ZH, Li YH, Chen JZ, Guo S, Wu Y, et al. Treatment of infraorbital dark circles using a low-fluence Q-switched 1,064- nm laser. Dermatol Surg. 2011;37:797-803.
- Vanaman Wilson MJ, Jones IT, Bolton J, Larsen L, Wu DC, Goldman MP, et al. Prospective studies of the efficacy and safety of the picosecond 755, 1,064, and 532 nm lasers for the treatment of infraorbital dark circles. Lasers Surg Med. 2018;50:45-50.
- Patil UA, Dhami LD. Overview of lasers. Indian J Plast Surg. 2008;41:S101-13.
- Farkas JP, Hoopman JE, Kenkel JM. Five parameters you must understand to master control of your laser/light-based devices. Aesthet Surg J. 2013;33(7):1059-64.
- Barkana Y, Belkin M. Laser eye injuries. Surv Ophthalmol. 2000;44(6):459-78.
- Hahn P, Schneider EW, Tabandeh H, Wong RW, Emerson GG. American Society of Retina Specialists Research and Safety in Therapeutics (ASRS ReST) Committee. reported complications following laser vitreolysis. JAMA Ophthalmol. 2017;135(9):973-6.
- Tassignon MJ, Kreissig I, Stempels N, Brihaye M. Indications for Q-switched and mode-locked Nd: YAG lasers in vitreoretinal pathology. Eur J Ophthalmol. 1991;1(3):123-30.
- Little HL, Jack RL. Q-switched neodymium: YAG laser surgery of the vitreous. Graefes Arch Clin Exp Ophthalmol. 1986;224(3):240-6.
- Wesolosky JD, Tennant M, Rudnisky CJ. Rate of retinal tear and detachment after neodymium: YAG capsulotomy. J Cataract Refract Surg. 2017;43(7):923-8.
- Grzybowski A, Kanclerz P. Does Nd: YAG capsulotomy increase the risk of retinal detachment? Asia Pac J Ophthalmol (Phila). 2018;7(5):339-44.
- Mirnezami SA, Rajaei Jafarabadi M, Abrishami M. Temperature distribution simulation of the human eye exposed to laser radiation. J Lasers Med Sci. 2013;4(4):175-81.
- Thach AB, Lopez PF, Snady-McCoy LC, Golub BM, Frambach DA. Accidental Nd: YAG laser injuries to the macula. Am J Ophthalmol. 1995;119(6):767-73.
- Harris MD, Lincoln AE, Amoroso PJ, Stuck B, Sliney D. Laser eye injuries in military occupations. Aviat Space Environ Med. 2003;74(9):947-52.
- Lam TT, Tso MO. Retinal injury by neodymium: YAG laser. Retina. 1996;16(1):42-6.
- Mainster MA, Stuck BE, Brown J. Assessment of alleged retinal laser injuries. Arch Ophthalmol. 2004;122(8):1210-17.
- Liu HF, Gao GH, Wu DC, Xu GD, Shi LS, Xu JM, et al. Ocular injuries from accidental laser exposure. Health Phys. 1989;56(5):711-6.
- Smalley PJ. Laser safety: Risks, hazards, and control measures. Laser Ther. 2011;20(2):95-106.
- Smalley PJ. Keys to building a safe and effective healthcare laser program. Laser Ther. 2018;27(1):11-20.
- Sachdev M, Britto GR. Essential requirements to setting up an aesthetic practice. J Cutan Aesthet Surg. 2014;7(3):167-9.
- Alam M. Who is qualified to perform laser surgery and in what setting? Semin Plast Surg. 2007;21(3):193-200.
- Jalian HR, Jalian CA, Avram MM. Common causes of injury and legal action in laser surgery. JAMA Dermatol. 2013;149(2):188-93.
- Kelsall D. Laser hair removal: No training required? CMAJ. 2010;182(8):743.
Article Type
Opinion Article
Publication History
Received Date: 15-08-2021
Accepted Date: 17-09-2021
Published Date: 24-09-2021
Copyright© 2021 by Au SCL, et al. All rights reserved. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Citation: Au SCL, et al. Cosmetic Laser Related Retinal Injuries. J Ophthalmol Adv Res. 2021;2(3):1-6.