Review Article | Vol. 6, Issue 3 | Journal of Clinical Medical Research | Open Access

The Impact of Layer Thickness on Key Parameters Affecting 3D-Printed Dental Materials: A Systematic Review


Sandy Hazko1
, Louis Hardan2,3, Naji Kharouf4,5, Carlos Enrique Cuevas-Suárez6*, Karim Corbani2,7, Hani Tohme3,8, Abigailt Flores-Ledesma9, Monika Lukomska-Szymanska10, Nicolas Nassar3,11,12, Rim Bourgi2,4,13*

1Surgical Department, Medizinische Hochschule Hannover, 30625 Hannover, Germany
2Department of Restorative, and Esthetic Dentistry, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
3Department of Digital Dentistry, AI, and Evolving Technologies, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
4Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
5Department of Endodontics, and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
6Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca 42160, Mexico
7Laser Unit, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
8Department of Removable Prosthodontics, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
9Dental Materials, and Biomaterials Laboratory, Faculty of Stomatology, Meritorious Autonomous University of Puebla, Puebla 72000, Mexico
10Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
11Craniofacial Research Laboratory, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
12Department of Orthodontics, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
13Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, Beirut 115020, Lebanon

*Correspondence author:Rim Bourgi, Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, and Lebanon, and Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, 115020 Beirut, Lebanon, and Department of Restorative, and Esthetic Dentistry, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon; Email: [email protected]; [email protected]

Citation: Hazko S, et al. The Impact of Layer Thickness on Key Parameters Affecting 3D-Printed Dental Materials: A Systematic Review. Jour Clin Med Res. 2025;6(3):1-21.

Copyright© 2025 by Hazko S, et al. All rights reserved. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Received
21 August, 2025
Accepted
08 September, 2025
Published
15 September, 2025

Abstract

Background: Three-dimensional (3D) printing has transformed restorative, and prosthetic dentistry, providing new possibilities for the fabrication of dental materials. Nevertheless, the influence of printing layer thickness on the final properties of dental resins remains insufficiently clarified.

Study Design (Methods): A systematic review was conducted through a comprehensive electronic search of PubMed, Scopus, and Web of Science up to June 2025. Eligible in-vitro studies investigated the effect of 3D printing layer thickness on the mechanical properties, dimensional accuracy, surface roughness, and bond integrity of dental resins. Thirty-seven studies met the inclusion criteria, and were analyzed narratively due to heterogeneity in study designs, materials, and testing methods.

Results: Printing layer thickness demonstrated a significant effect on dental resin performance. Thinner layers (25-50 µm) were generally associated with enhanced flexural strength, hardness, surface smoothness, and color stability. However, in some composite-based materials, thicker layers yielded superior mechanical properties. Dimensional accuracy, and marginal fit varied across studies, with some reporting optimal results at 50 µm, and others at 100 µm.

Conclusion: Layer thickness represents a critical parameter influencing the performance of 3D-printed dental resins. Optimal outcomes depend on a balance between layer thickness, build angle, and post-curing protocols. Further standardized investigations, including clinical studies, are essential to establish evidence-based guidelines for layer thickness selection in dental additive manufacturing.

Keywords: 3D Printing; Additive Manufacturing; Dental Biomaterials; Layer Thickness

Introduction

Three-Dimensional (3D) printing has seen remarkable progress in recent years, becoming more accurate, and reliable, which has made it an increasingly attractive tool in the medical field. In dentistry, additive manufacturing enables the rapid fabrication of customized devices, ranging from surgical guides, and orthodontic appliances to provisional, and definitive restorations. Compared with conventional subtractive techniques, 3D printing offers advantages such as reduced material waste, enhanced design flexibility, and the ability to reproduce complex geometries with high precision. These developments have accelerated its integration into both clinical, and laboratory workflows. Its versatility has opened new doors in healthcare, with applications ranging from medicine, and dentistry to orthopedics, tissue engineering, and the creation of medical devices [1-3]. At the heart of this technology is the ability to transform digital designs into physical objects-starting with a 3D model in Standard Tessellation Language (STL) format, which is then built layer by layer by bonding, joining,, or curing small amounts of material [4].

In dentistry, several 3D printing technologies have become widely used, with Stereolithography (SLA), and Digital Light Processing (DLP) standing out as the most common [5]. Other methods include Fused Deposition Modeling (FDM), Powder Bed Fusion (PBF), laser powder forming, and inkjet printing, each differing mainly in the materials they use, and how they build layers to form a 3D object [6,7].

SLA, one of the earliest 3D printing techniques introduced in 1986, works through a photopolymerization process. It uses a photosensitive liquid resin cured layer-by-layer with Ultraviolet (UV) light, or a laser to gradually build a solid structure on a platform. Each cured layer bonds to the previous one, creating a strong, cohesive object [5].

DLP shares many similarities with SLA but replaces the laser with a digital light projector to cure the resin [8]. This change offers significant benefits: DLP can cure an entire layer at once, affectedly speeding up the printing process. It also tends to be more cost-effective since it uses less material compared to SLA, and other 3D printing techniques [5]. Currently, DLP is widely adopted in dental applications, such as producing precise models from digital impressions, surgical guides, castable restorations, splints, and even temporary crowns. Given its combination of speed, accuracy, and cost-efficiency, DLP’s role in dentistry is expected to continue growing rapidly [5]. The efficiency of 3D printing is influenced by several factors, including layer thickness, laser intensity, and speed, build angle, the design of support structures, and the specific printing technology used (Table 1) [9-14].

Several studies have assessed the influence of layer thickness on the properties of 3D-printed dental materials [15-25]. Models printed using SLA, and DLP technologies at various layer heights have been shown to remain within clinical accuracy limits [15,16]. Layers of 100 µm exhibited less deviation than finer ones [15,16], improved flexural, and tensile strength, better degree of conversion, and color stability, and shorter printing time [5,19-21]. Hence, layers of 50 µm were found to have superior mechanical properties, and marginal fit [5,22,23]. Beyond mechanical performance, advances in 3D printing have also targeted esthetic outcomes, with new strategies such as integrated color rendering mechanisms using adaptive colored layer sequencing, which improve color reproduction quality by considering both global, and local model characteristics [17]. Additionally, 50 µm layers were determined to reduce surface roughness, contact angle, and microbial adhesion compared to 100 µm in high-viscosity DLP denture bases [25]. Çakmak, et al., revealed that milled interim crowns had better margin quality than printed ones, especially at 20 µm, and 100 µm [24]. Collectively, these findings underscore the importance of selecting an appropriate layer thickness to optimize the mechanical, esthetic, and biological outcomes of dental 3D printing. As previously highlighted, several key factors significantly influence the reliability of 3D-printed materials in dentistry. These include the accuracy of the print, the material’s mechanical strength, the speed of printing, the chosen layer thickness, and the specifics of the curing process [9,12,26-29]. Selecting the appropriate 3D printing material ultimately depends on the intended dental application. For instance, materials used in dental restorations should exhibit strength, resistance to degradation, biocompatibility, and esthetics [30].

Given the diversity of findings across different studies, and printing protocols, there is a pressing need to synthesize the current evidence to clarify how layer thickness variations affect the performance of 3D-printed dental materials [15-25]. Therefore, this systematic review aims to assess the impact of different 3D printing layer thicknesses on key material properties including mechanical strength, dimensional accuracy, surface roughness, and bond integrity in in-vitro studies involving dental resins.

Ethical Statement

The project did not meet the definition of human subject research under the purview of the IRB according to federal regulations, and therefore, was exempt.

Materials, and Methods

Study Design

This systematic review, and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews, and Meta-Analyses (PRISMA) guidelines, and the Cochrane Handbook for Systematic Reviews of Interventions [21]. The study protocol was registered in the Open Science Framework (OSF) under the identifier DOI: 10.17605/OSF.IO/GW68P.

The research question was formulated using the PICOT framework:

Population (P): 3D-printed dental materials.

Intervention (I): Use of different layer thicknesses during the 3D printing process.

Comparison (C): Standard, or alternative layer thicknesses.

Outcome (O): Mechanical properties.

Time/Study Design (T): In-vitro studies.

The research question guiding this study was: “How does the variation in layer thickness during the 3D printing process influence the properties of 3D-printed dental materials in in-vitro studies?”.

Search Strategy

A comprehensive electronic search was used to identify relevant in-vitro studies using major scientific databases (e.g., PubMed, Scopus, Web of Science). The search included studies published up to June 3, 2025.

Search

Keywords

# 1

3D printing, or 3D-printing, or 3D-printed dental resin, or additive manufacturing, or additive manufacturing technologies, or 3D printing manufacturing, or 3D printing resin, or 3D print resin, or 3D-printed materials, or 3-dimensional printing

# 2

Thickness, or layer thickness, or print layer thickness

# 3

tensile test, or microtensile strength, or microtensile bond strength, or micro-tensile strength, or shear bond strength, or microshear bond strength, or compression test, or flexural strength, or elastic modulus, or hardness, or mechanical tests, or mechanical properties, or degree of conversion, or polymerization, or wear resistance, or color stability, or dimensional stability, or trueness, or accuracy, or marginal fit, or margin quality, or surface roughness, or surface properties, or contact angle, or cell adhesion, or bond, or bonding, or dental bonding, or bonding efficacy, or bond strength, or bonding performance, or bonding effectiveness, or bond performance, or bonding properties, or adhesive properties

# 4

# 1, and # 2, and # 3

Table 1: Search strategy used.

Study Selection

Two independent reviewers (RB, and CECS) assessed titles, and abstracts based on these inclusion criteria: (1) In-vitro studies reporting the effect of layer thickness variation on the properties of 3D-printed dental materials; (2) Evaluated at least one outcome parameter; (3) Included a comparison between at least two different layer thicknesses; (4) Included quantitative data with mean, and standard deviation values; (5) Published in English, Spanish, or Portuguese.

Studies were excluded if they were case reports, case series, pilot studies, reviews,, or did not meet the specified inclusion criteria. Full-text articles were retrieved for studies that met the inclusion criteria, or if eligibility was unclear. Any discrepancies between reviewers were addressed through discussion, or consultation with a third reviewer (LH).

Data Extraction

Data extraction was performed using a standardized form, including: Study, and year, Materials tested, Printer used, Layer thickness tested, Properties evaluated, and Main results.

Quality Assessment

The risk of bias in the selected studies was evaluated using the Quality Assessment Tool for In-Vitro Studies (ROBDEMat) [22], which addresses four main domains: D1 – planning, and allocation, D2 – sample/specimen preparation, D3 – outcome assessment, and D4 – data analysis, and reporting.

Domain D1 includes three criteria: the use of an appropriate control, or reference group, randomization of specimens, and justification of the sample size.

Domains D2, D3, and D4 each involve two criteria. Specifically, D2 focuses on standardization of methodology, and experimental conditions; D3 considers reproducibility, and the presence of operator blinding; while D4 examines the adequacy of statistical analyses, and the clarity of outcome reporting.

Each criterion was scored as “sufficiently reported,” “insufficiently reported,” “not reported,”, or “not applicable.” Two reviewers (RB, and NN) conducted the assessment independently, and disagreements were resolved by discussion or, if necessary, with the input of a third reviewer (MLS) until consensus was achieved [22].

Results

Search Strategy

A comprehensive search across all databases initially identified 7,366 records. Following the removal of duplicates, 5,625 unique publications were retained for preliminary screening. After evaluating titles, and abstracts, 5,571 studies were excluded for not meeting the inclusion criteria. This left 54 articles for full-text assessment. Of these, 17 were excluded because the full-text cannot be retrieved. A detailed overview of the selection process is illustrated in the PRISMA flowchart (Fig. 1).

Figure 1: PRISMA flowchart.

Main Findings

This systematic review synthesized data from various in-vitro studies investigating the effect of layer thickness on the properties of 3D-printed dental materials [5,20,31-65]. The included studies evaluated a range of materials, including denture base resins, interim crown/FPD resins, PLA, ABS, PETG, and stainless steel. Diverse 3D printers, such as Asiga, NextDent, Formlabs, SISMA, Zaxe, and Flashforge, were utilized across the studies.

Although these studies were performed in-vitro, their findings carry important clinical implications. Variations in printing layer thickness were shown to influence mechanical strength, dimensional accuracy, and surface quality, which are critical for the long-term success of dental restorations. For example, in interim crowns, and fixed partial dentures, optimal layer thickness can improve marginal fit, and resistance to fracture, while in denture bases, it may enhance adaptation, and patient comfort. Simi-larly, in orthodontic, or surgical applications, accuracy related to layer thickness directly impacts treatment precision. These outcomes highlight the translational value of in-vitro results to clinical scenarios, where material properties strongly determine restoration performance, esthetics, and patient satisfaction.

The assessed layer thicknesses varied significantly, ranging from 20 µm to 2 mm, with common thicknesses including 25, 50, and 100 µm. The properties evaluated were extensive, covering mechanical strength (e.g., flexural, tensile, compressive strength, hardness, fracture resistance, wear resistance), dimensional accuracy (trueness, precision, marginal/internal gap), surface characteristics (roughness, wettability), optical properties (color stability, translucency, scattering, absorption), and degree of conversion.

Key findings demonstrated that layer thickness plays a crucial role in determining the properties of 3D-printed dental materials. Thinner layers (25-50 µm) were frequently associated with greater flexural strength, and hardness in denture base resins. In contrast, certain materials exhibited superior mechanical performance at thicker settings, such as 0.64 mm for CF/PLA composites, and 0.7 mm for shape memory resin flexural strength. Surface roughness typically decreased with thinner layers, contributing to smoother finishes. Dimensional accuracy, and marginal fit yielded mixed results: while some studies identified 50 µm as optimal for adaptation, others reported that 100 µm enhanced trueness, and precision. Optical outcomes, including color stability, and translucency, were also influenced by layer thickness, often showing improvement with thinner layers. Furthermore, the degree of conversion was affected not only by the printing layer thickness but also by the post-curing protocol employed. Overall, the studies highlight the critical role of layer thickness, often alongside other printing parameters like build angle, in determining the final performance of 3D-printed dental materials (Table 2).

Study, and Year

Materials Tested

Printer Used

Layer Thicness Tested

Properties Evaluated

Main Results

AlRumaih, 2024 [31]

Denture Base Resins

Asiga (Asiga, Alexandria, New South Wales, Australia)

NextDent 5100 (NextDent by 3D Systems, Soesterberg, Netherlands)

Form 3+ (Formlabs Inc., Somerville, Massachusetts, USA)

25 µm, 50 µm, and 100 µm

Flexural strength, Hardness

– 25 µm, and 50 µm showed significantly higher flexural strength than 100 µm in all resins. 
– 25 µm, and 50 µm significantly increased hardness in NextDent, and FormLabs. 
– For ASIGA, only 25 µm had significantly higher hardness than 50 µm, and 100 µm.

Alshamrani, 2022 [5]

A2 EVERES TEMPORARY (SISMA, Italy)

EVERES ZERO (SISMA, Schio, Vicenza, Italy)

25 µm, 50 µm, 100 µm

Flexural strength (3-point bending), Vickers microhardness (VHN), Degree of Conversion (DC%)

– 100 µm showed the highest flexural strength (up to 94.60 MPa with dry storage). 
– Highest VHN observed in 100 µm + heat curing for 5 min (VHN = 17.95). 
– Highest degree of conversion observed at 50 µm (42.84%). 
– Both layer thickness, and post-printing conditions significantly affected mechanical properties.

Ayrilmis, 2018 [32]

Wood flour/Polylactic Acid (PLA) filament (1.75 mm diameter)

Zaxe 3D (Zaxe 3D Printer Company, Istanbul, Turkey)

0.05 mm, 0.1 mm, 0.2 mm, 0.3 mm

Surface roughness (Ra, Rz, Ry), Wettability (contact angle)

– Surface roughness decreased with decreasing layer thickness (i.e., smoother surfaces at 0.05 mm). 
– Wettability increased (higher contact angle) with increasing layer thickness. 
– Printing layer thickness significantly influences both surface texture, and wetting behavior.

Vinoth Babu, 2022 [33]

Carbon fiber/polylactic acid (CF/PLA) composite

Fused Deposition Modeling (FDM) 3D printer (model/manufacturer not specified)

0.08 mm, 0.25 mm, 0.64 mm

Tensile strength, Flexural strength, Interlaminar shear strength (ILSS), Surface roughness

– Best mechanical properties observed at 0.64 mm layer thickness, and 60% infill density with rectilinear, and hexagonal patterns.
– Thinner layers caused poor fiber-matrix bonding leading to fiber pull-out failure.
– Slicing parameters strongly affect mechanical performance, and failure mode.

Bakardzhiev, 2024 [34]

PLA, Acrylonitrile Butadiene Styrene (ABS), Polyethylene Terephthalate Glycol-modified (PETG) filaments (1.75 mm diameter)

Flashforge Creator Pro 2 (Flashforge Ltd., Jinhua, Zhejiang, China)

0.1 mm, 0.5 mm, 0.3 mm, 0.02 mm, 0.58 mm,

Surface roughness, print quality

Layer thickness had the greatest impact on surface roughness, and print quality; extrusion temperature, and printing speed had smaller effects.

Çakmak, 2024 [35]

Interim fixed partial dentures (FPDs) resin

NextDent C&B MFH (NextDent by 3D Systems, Soesterberg, Netherlands)

20 µm, 50 µm, 100 µm

Trueness (RMS deviation at external, intaglio, marginal, occlusal surfaces)

– 100 µm layer thickness showed highest deviations (lowest trueness) overall, and on most surfaces.
– No significant difference in marginal trueness among groups.
– Subtractive manufacturing (milled FPDs by Upcera) showed highest trueness compared to all additive groups.

Çakmak, 2021 [36]

3D-printed interim crowns made of composite resin based on acrylic esters with inorganic microfillers; milled crowns fabricated from polymethylmethacrylate (PMMA) discs.

MoonRay S100 (SprintRay Inc., Los Angeles, California, USA)

20 µm, 50 µm, 100 µm

Trueness (RMS deviations), Margin quality (stereomicroscope grading)

– Layer thickness affected trueness, and margin quality of 3D-printed crowns. 
– Milled crowns showed higher trueness on intaglio, and occlusal surfaces than 100 µm printed crowns. 
– Milled crowns had the highest margin quality overall. 
– 20 µm, and 100 µm printed crowns showed lowest margin quality, varying by margin location.

Corbani, 2020 [37]

Nanocomposite resin crowns (3D-printed, and milled composite)

DFAB (DWS, Thiene, Italy)

0.5 mm, 1.0 mm, 1.5 mm

Fracture resistance, failure pattern

– 3D-printed crowns showed significantly higher fracture resistance than milled crowns at all thicknesses.
– Both groups had higher fracture resistance with increased thickness.
– Highest fracture loads at 1.5 mm thickness.
– More irreparable fractures observed at 1.5 mm thickness.

Cremonin, 2025 [38]

Thermoformed Aligners

3D-Printed

Aligners

Nexa3D Xip printer (Nexa3D, Ventura, CA, USA)

0.65-0.95 mm (3D-printed); uniform (thermoformed)

Retention force (Tensile test)

3D-printed aligners with high margins, and gradients had higher retention; scalloped thermoformed aligners had the lowest retention.

de Gois Moreira, 2025 [39]

Resin for provisional restorations

Form 2 (Formlabs Inc., Somerville, Massachusetts, USA)

25 µm, 50 µm, 100 µm

Flexural strength (σ), flexural modulus (E), precision, surface topography (micro-CT, profilometry, scanning electron microscopy (SEM))

25 µm layer thickness with 90°, and 45° build angles showed highest flexural strength, and precision. 
0°/25 µm group showed highest shrinkage. 
30°/25 µm group had highest surface roughness. 
60° angle groups had lowest porosity.

Diken Türksayar, 2024 [40]

V-Print Splint resin (3D-printed occlusal splints)

SolFlex 350 (W2P Engineering GmbH, Vienna, Austria)

50 µm, 75 µm, 100 µm

Wear resistance (volume loss via 2-body wear test); SEM evaluation

Polishing significantly reduced wear (p = 0.003). Layer thickness had no significant effect (p = 0.105). D50-polished had lowest wear. 100 µm thickness may be preferred for faster printing.

Espinar, 2023 [41]

DFT- Detax Freeprint

Temp (DETAX GmbH,

Ettlingen, Germany), FT- Formlabs

Temporary CB (Formlabs Inc.,

Somerville, MA, USA)

FP- Formlabs

Permanent Crown (Formlabs Inc.,

Somerville, MA, USA), GCT- GC TempPrint (GC Corporation, Tokyo,

Japan)

Asiga Max UV1

(Asiga HQ,

Alexandria, NSK, Australia), 3D Form 3B+2

(Formlabs Inc.,35

Medford, Somerville, MA 02143, USA)

0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm

Scattering (S), Absorption (K), Albedo (a), Transmittance (T%), Reflectivity Index (RI), Infinite Optical Thickness (X∞) using Kubelka-Munk model

Optical properties were wavelength-dependent, and varied significantly with thickness, and printing angle (0° vs 90°). S, and K increased with thickness; T%, and X∞ decreased. Orientation influenced RI, S, K, and X∞ values at certain thicknesses. These variations impact the biomimetic potential of 3D-printed resins, and should be considered for clinical use.

Zoltan Farkas, 2023 [42]

NextDent C&B Micro-Filled Hybrid (NextDent B.V., Netherlands, Soesterberg)

ANYCUBIC Photon Mono x

(Anycubic,China, Shenzhen)

0.05 mm, and 0.1 mm

Tensile strength, Compression strength

Brittle behavior was observed in all tensile specimens. Highest tensile strength occurred with 0.05 mm layer thickness. Both layer direction (0°, 45°, 90°), and thickness influenced mechanical properties, allowing optimization for clinical application.

Farzadi, 2014 [43]

Calcium sulfate-based powder

3DP machine (Z450, Z Corporation, USA)

0.0875, 0.1, 0.1125 and

0.125 mm

Compressive strength, Toughness, Young’s modulus, Dimensional accuracy (via SEM & µCT)

Best mechanical, and structural performance was observed with 0.1125 mm, and 0.125 mm layer thickness. X-axis orientation gave highest dimensional accuracy, and best match with CAD model for pore size, porosity, and pore interconnectivit.

Fouda, 2025 [44]

Formlabs denture

base resin (FormLabs, Somerville, MA, USA), V-print dentbase (VOCO, Cuxhaven,

Germany), Conventionally pressable resin material PalaXpress, (Kulzer, Hanau, Germany)

Form

3 (Formlabs Inc., Somerville, Massachusetts, USA), P30 (Straumann, Rapid Shape, Heimsheim, Germany)

50 µm, 100 µm (only for Formlabs denture

base resin), 50 µm (for V-print dentbase )

Flexural strength, Surface roughness (Ra, Rz), Hardness (HM, HV2), before, and after thermocycling

Build angle, and thermocycling significantly affected flexural strength. Layer thickness had no significant effect for FL. ISO 20795-1 (≥65 MPa) was exceeded by PP (70.5 MPa), FL at 90° (69.3 MPa), and VC at 0° (69.0 MPa). Proper build angle selection is key for strength, and clinical performance.

Gad, 2024 [45]

Asiga DentaBASE (Asiga, Erfurt, Germany) with 0%, 0.25%, 0.5% SiO₂NPs, and NextDent Denture 3D+ (NextDent B.V.,

Soesterberg, The Netherlands)with 0%, 0.25%, 0.5% SiO₂NPs

Asiga MAX UV (Alexandria, New South Wales, Australia)
NextDent 5100 (Nexa3D, Ventura, CA, USA)

50 µm, 75 µm, 100 µm

Flexural strength (3-point bending), SEM fracture analysis

Flexural strength was highest at 50 µm, and 75 µm, lowest at 100 µm for both resins. SiO₂NP addition significantly improved strength at 50, and 75 µm, but had no significant effect at 100 µm. Best values: Asiga 0.25%/50 µm (97.32 MPa), NextDent 0.5%/50 µm (97.54 MPa). SEM showed more lamellae/irregularities with thinner layers, and added nanoparticles.

García-Gil, 2025 [46]

SLA resin for maxillary hollow master casts

Form 2 (Formlabs, Somerville, MA, USA)

50 µm, and shell thickness (2 mm, and 4 mm)

Accuracy (trueness, and precision), RMS error of printed casts vs STL reference

No significant effect of print orientation (0°, 10°, 20°), or shell thickness on accuracy of SLA casts.

Grymak, 2023 [47]

DentaCAST (Asiga, Australia),

SuperCAST (Asiga, Australia), and NextDent (3D Systems, Netherlands)

Asiga 4 K 3D printer (Sydney, Australia)

50 µm, 75 µm, 100 µm

Accuracy (RMSE), dimensional discrepancies, print failures

Optimal accuracy at 45° build angle, and middle plate position. Clinically acceptable RMSE: SuperCAST 50 µm (98 ±35 µm), NextDent 75 µm (143 ±14 µm), DentaCAST 100 µm (115 ±19 µm). Higher discrepancies at 0°. Layer thickness most significant factor for accuracy.

Hasanzade, 2023 [48]

Interim crowns

Digident Plus (Digident Co., Ltd., South Korea, Seoul)

25 µm, 50 µm, 100 µm

Marginal gap, Internal gap (axial, occlusal)

50 µm layer thickness yielded best marginal, and internal fit. 100 µm had significantly higher marginal, and occlusal gaps; 25 µm had larger axial gap than 50 µm.

Iyibilgin, 2025 [49]

316L stainless steel filament

Printer (Zaxe, Istanbul, Türkiye)

100 µm, 200 µm, 300 µm, 400 µm

Tensile strength, Hardness, Density, Phase analysis

Tensile strength, and hardness increased with decreasing layer thickness; highest tensile strength (432 MPa), and hardness (213 Hv) at 100 µm layer thickness.

Khalil, 2025 [50]

Shape memory resin for direct aligners

NBEE printer (Uniz, California, USA)

0.5 mm, and 0.7 mm

Flexural strength (3-point bending)

No significant difference in flexural strength among printing orientations (vertical, horizontal, 30°, 45°). 0.7 mm thickness showed significantly higher strength.

Kul, 2025 [51]

3D-printed acrylic denture base resin

Not specified

2 mm, and 3 mm

Flexural strength, and colour stability (ΔE00)

Highest flexural strength (95 MPa) was achieved with 3 mm specimens cured at 80 °C for 60 min. However, 2 mm specimens showed better colour stability (ΔE00 = 2.59).

Li, 2023 [52]

3D‑printed denture base polymer

Solflex 350 plus (W2P Engineering GmbH, Vienna, Austria)

25 µm, 50 µm, 100 µm

Surface roughness (Sa) via SEM & Sa metrics; Candida albicans adhesion

Surface roughness significantly impacted by both layer thickness, and build angle (Sa: F(4,45)=90.77, p<0.0001). Candida adhesion significantly affected by layer thickness (F(2,99)=6.96, p=0.0015), but not by build angle. Thinner layers improved both surface smoothness, and reduced microbial adhesion.

Liu, 2021 [53]

PLA custom trays

Lingtong II (SHINOTECH, Shenzhen, China,)

0.1 mm, 0.2 mm, 0.3 mm, 0.4 mm, 0.5 mm

Tensile bond strength, flexural strength, tensile strength, dimensional accuracy, print time, SEM analysis of fracture surfaces

Bond strength increased with thickness up to 0.4 mm, then decreased.
Flexural, and tensile strengths declined as thickness increased.
Dimensional accuracy stable (0.1-0.4 mm), but worsened at 0.5 mm.
Print time decreased significantly with thicker layers.
Fracture SEM suggested weaker layer bonding at extremes of thickness.

Mahajan, 2025 [54]

Interim crowns for maxillary left central incisor, D-Tech crown, and bridge resin

Asiga 3D printer (Asiga, Alexandria, New South Wales, Australia)

50, 75, 100 µm

Color stability, surface roughness (Ra)

100 µm showed greatest color stability; 50 µm showed least.
Surface roughness increased with layer thickness.

Mushtaq, 2023 [55]

ABS

CR5-3D printer

(Creality, Shenzhen, china)

0.05-0.4 mm

Flexural strength, tensile strength, surface roughness, print time, energy consumption

Layer thickness influenced surface roughness, and print time; infill density affected mechanical properties. Optimal settings: LT=0.27 mm, ID=84%, PS=51.1 mm/s, FS=58.01 MPa, TS=35.8 MPa, Ra=8.01 µm, print time=58 min, energy=0.21 kWh.

Park, 2023 [56]

Thermoformed: Polyethylene terephthalate glycol, Copolyester-elastomer (TM); 3D-printed: TC-85 resin cleaned with alcohol (PA), and centrifuge (PC)

Asiga MAX

(Asiga, Alexandria,

Australia)

SprintRay Pro 95

(SprintRay, Los Angeles, CA)

~614 µm (alcohol-cleaned), ~688 µm (centrifuge-cleaned)

Thickness, Gap Width (micro-CT), Translucency (spectrophotometry)

PC group had higher translucency than PA; thickness decreased after thermoforming, increased in 3D prints; TM had smallest gap; cleaning affects properties.

Reymus, 2019 [20]

NextDent C&B resin for temporary restorations (NextDent B.V., Netherlands, Soesterberg)

D20 II (Rapid Shape, Heimsheim, Germany)

25 µm, 50 µm, 100 µm

Degree of Conversion (DC), ΔDC, effect of post-curing methods

Post-curing method highly influenced DC; Otoflash G171 (OF) gave highest DC, and ΔDC; 50, and 100 µm layers showed higher ΔDC than 25 µm.

Sasany, 2024 [57]

VarseoSmile Crown Plus (Bego; Bremen, Germany), Crowntec (Saremco Dental; Aschau, Germany), GC Temp PRINT (GC Dental; Tokyo, Japan), NextDent C&B MFH (NextDent; Soesterberg, Netherlands)

MAX UV

(Asiga, Alexandria,

Australia)

25 μm, 50 μm, 100 μm

25 μm, 50 μm, 100 μm

25-, and 50-μm thicknesses showed color properties closer to target shade; 100-μm thickness showed lower translucency, and higher surface roughness.

Shergill, 2023 [58]

PLA, ABS, Polyethylene Terephthalate Glycol

Ultimaker 2+ printer (Ultimaker, Utrecht, The Netherlands)

0.12, 0.16, 0.20, 0.28 mm

Mechanical properties (tensile strength)

Increasing layer thickness decreased mechanical properties in ABS, and PLA, with PLA showing more significant effects. PETG showed less significant changes. Differences attributed to layer adhesion, and structural defects from the additive process.

Sousa, 2021 [59]

Poly(lactic acid) recycled (rPLA), Poly(methyl methacrylate) (PMMA), High impact polystyrene (HIPS), Thermoplastic polyurethane (TPU), Ethylene-vinyl acetate (EVA, control) for protective mouthguards

3D Robo R2 printer (San Diego, California, USA)

2 mm, 4 mm

Chemical, thermal, surface, mechanical (impact strength, energy absorption)

Impact strength decreased with thickness increase except TPU; TPU showed highest deformation capacity, and similar energy absorption to EVA; other polymers had higher energy absorption than EVA.

Wu, 2025 [60]

Direct 3D-printed clear aligner resin

Uniz NBEE printer (Uniz, CA, USA)

50 µm, 100 µm

Mechanical properties (tensile stress, strain, modulus), color stability, surface roughness

50 µm layer + 90° orientation showed best color stability in artificial saliva. Coffee staining affected all. Mechanical properties, and surface roughness improved with build orientation order: 90° > 60° > 45°. Significant differences (p < .05).

Yang, 2022 [61]

Three-unit resin prostheses

Zenith U (Dentis, Daegu, Korea)

50 µm, 100 µm

Marginal fit (marginal gap, and absolute marginal discrepancy)

Build orientation significantly affected marginal fit; 45° better than 60°. Layer thickness had no significant effect. Marginal fit affected by pontic area.

Yilmaz, 2022 [62]

Removable dies (resin)

MAX UV

(Asiga, Alexandria,

Australia)

50 µm, 100 µm, 50-100 µm combined

Trueness (RMS), Fit of removable dies on cast

50-100 µm group had higher overall RMS than 100 µm. 100 µm had highest crown RMS; 50 µm had highest root RMS. 50 µm group showed best crown trueness on cast. Differences clinically small; 100 µm recommended for efficiency.

Yilmaz, 2024 [63]

3D-CB, 3D-TH, 3D-CT (additive); G-CAM, VE (subtractive)

MAX UV

(Asiga, Alexandria,

Australia)

1 mm, 1.5 mm, 2 mm

Color change (ΔE₀₀), Relative Translucency Parameter (RTP)

3D-TH showed the highest ΔE₀₀, G-CAM the lowest. Color change increased with AM vs. SM. Translucency (RTP) decreased with increased thickness, and coffee thermocycling. 3D-TH had most unacceptable changes, while G-CAM was more color stable, and translucent.

You, 2021 [64]

Trial dentures (resin)

Zenith U (Dentis, Daegu, Korea)

50 µm, and 100 µm

Trueness, and precision (RMS values of intaglio, and cameo surfaces)

100 µm layer thickness yielded significantly better trueness, and precision for cameo surfaces. No significant difference in intaglio surface precision. 100 µm recommended.

Zhang, 2019 [65]

3D printed dental models (from scanned digital dental models)

EvoDent (UnionTech, Shanghai, China); EncaDent (Encashape, WuXi, China); Vida HD (EnvisionTEC, Dearborn, MI, USA); Form 2 (Formlabs, Somerville, MA, USA)

20, 25, 30, 50, 100 µm (depending on printer)

Printing accuracy (3D comparison with STL)

50 µm was optimal for DLP. DLP had better accuracy, and speed at 100 µm than SLA. EvoDent 50 µm showed highest accuracy. Form 2 at 100 µm showed lowest accuracy.

Table 2: Characteristics of the studies included in the review.

Risk of Bias

The risk of bias assessment revealed that most studies exhibited unclear, or high risk in planning, and allocation due to insufficient reporting, while outcome assessment, and data reporting domains demonstrated a consistently high risk of bias, highlighting concerns regarding the validity, and reliability of the reported results (Table 3).

Study

D1. Bias in planning, and allocation

D2. Bias in sample/ specimen preparation

D3. Bias in outcome assessment

D4. Bias in data treatment, and outcome reporting

1.1

1.2

1.3

2.1

2.2

3.1

3.2

4.1

4.2

Study, and Year

         

AlRumaih, 2024 [31]

NR

NR

R

R

R

R

NR

R

R

Alshamrani, 2022 [5]

R

NR

NR

R

R

R

NR

R

R

Ayrilmis, 2018 [32]

NR

R

NR

R

R

R

NR

R

R

Vinoth Babu, 2022 [33]

NR

NR

NR

R

R

R

NR

IR

R

Bakardzhiev, 2024 [34]

NR

NR

NR

R

R

IR

NR

IR

R

Çakmak, 2024 [35]

R

NR

IR

R

R

R

NR

R

R

Çakmak, 2021 [36]

R

R

IR

R

R

R

R

R

R

Corbani, 2020 [37]

NR

R

NR

R

R

R

NR

R

R

Cremonin, 2025 [38]

NR

NR

R

R

R

R

NR

R

R

de Gois Moreira, 2025 [39]

NR

R

R

R

R

R

NR

R

R

Diken Türksayar, 2024 [40]

NR

NR

R

R

R

R

NR

R

R

Espinar, 2023 [41]

NR

NR

NR

R

R

R

NR

R

R

Zoltan Farkas, 2023 [42]

NR

NR

NR

R

R

R

NR

IR

R

Farzadi, 2014 [43]

NR

NR

NR

R

R

R

NR

R

R

Fouda, 2025 [44]

R

NR

NR

R

R

R

NR

NR

R

Gad, 2024 [45]

NR

NR

R

R

R

R

NR

R

R

García-Gil, 2025 [46]

NR

NR

NR

R

R

R

NR

R

R

Grymak, 2023 [47]

R

R

R

R

R

R

NR

R

R

Hasanzade, 2023 [48]

NR

NR

NR

R

R

R

R

R

R

Iyibilgin, 2025 [49]

NR

NR

NR

R

R

R

NR

R

R

Khalil, 2025 [50]

NR

R

NR

R

R

R

NR

R

R

Kul, 2025 [51]

NR

NR

R

R

R

R

NR

R

R

Li, 2023 [52]

R

R

R

R

R

R

NR

R

R

Liu, 2021 [53]

R

NR

NR

R

R

R

NR

R

R

Mahajan, 2025 [54]

R

NR

R

R

R

R

NR

R

R

Mushtaq, 2023 [55]

NR

NR

NR

R

R

R

NR

R

R

Park, 2023 [56]

NR

NR

NR

R

R

R

NR

R

R

Reymus, 2019 [20]

NR

NR

NR

R

R

R

NR

R

R

Sasany, 2024 [57]

NR

NR

R

R

R

R

NR

R

R

Shergill, 2023 [58]

NR

NR

NR

R

R

R

NR

R

R

Sousa, 2021 [59]

R

NR

NR

R

R

R

NR

R

R

Wu, 2025 [60]

NR

NR

NR

R

R

R

NR

R

R

Yang, 2022 [61]

NR

NR

NR

R

R

R

NR

R

R

Yilmaz, 2022 [62]

NR

NR

NR

R

R

R

NR

R

R

Yilmaz, 2024 [63]

NR

NR

NR

R

R

R

NR

R

R

You, 2021 [64]

NR

NR

NR

R

R

R

NR

R

R

Zhang, 2019 [65]

NR

R

IR

R

R

R

NR

IR

R

Table 3: Quality analysis of studies included in the systematic review, separated by their risk of bias in different domains. R – sufficiently reported/adequate; NR – not reported; IR – insufficiently reported;, and NA – not applicable.

Bias sources within each domain: 1.1 – use of control group; 1.2 – sample randomization; 1.3 – justification of sample size; 2.1 – standardization of materials/samples; 2.2 – uniformity of experimental conditions; 3.1 – consistency in testing procedures/outcomes; 3.2 – blinding of the operator; 4.1 – statistical evaluation; 4.2 – reporting of results.

Discussion

3D printing software allows control over the thickness of each printed layer, commonly referred to as layer height, or print resolution. This layer thickness significantly affects both the number of layers required to build the object, and the total printing time. Typically, layer heights can vary from about 20 to 175 micrometers (µm), or more. Smaller layer heights result in more layers, which can enhance the level of detail, and create smoother surfaces. However, this also means longer print durations. It is important to balance these benefits against potential drawbacks: with each additional layer, there is an increased chance of curing errors that may lead to distortions, or even print failures. Therefore, optimizing layer thickness is crucial to achieving a balance between print quality, and efficiency [5,14].

The present systematic review underscores the significant influence of printing layer thickness on the performance characteristics of 3D-printed dental materials. As additive manufacturing becomes increasingly integral to prosthetic dentistry, understanding how layer thickness affects mechanical strength, dimensional accuracy, surface properties, optical characteristics, and polymerization is crucial to optimizing clinical outcomes [15-25].

Dimensional Accuracy, and Marginal Fit

Dimensional accuracy, and marginal adaptation are critical factors for the clinical success of fixed prostheses, as they influence fit, longevity, and biological compatibility. Research shows that the optimal layer thickness for these properties varies across studies. While some investigations indicate that thinner layers (~50 µm) improve trueness, and marginal fit by enabling finer details, and smoother surface transitions, other studies report that 100 µm layers can achieve comparable, or even superior outcomes, depending on the printer resolution, and resin type [13,16,23,24]. This inconsistency is likely due to differences in printer calibration, resin viscosity, build orientation, and post-processing protocols [11,13]. For instance, build angle interacts with layer thickness to influence polymerization shrinkage, and dimensional distortion, factors critical for precise fit [27]. Additionally, thicker layers may reduce cumulative errors by decreasing the number of layers, consequently, the interlayer bonding interfaces that can cause distortion. Song, et al., found that increased layer thickness shortened printing time but sometimes at the cost of surface detail, highlighting the trade-offs involved [19].

Degree of Conversion, and Post-Processing

The degree of conversion (DC) of resin monomers to polymers directly impacts mechanical durability, and biocompatibility. Reymus, et al., demonstrated that thinner layers generally achieve higher DC due to better light penetration, and reduced attenuation in each layer, improving polymer network formation [20]. However, post-curing protocols light intensity, time, and temperature-also critically influence DC, sometimes overriding the effects of layer thickness [5,20]. Clinicians should, therefore, carefully calibrate post-processing to complement printing parameters for optimal material performance.

Mechanical Properties

A consistent finding across multiple studies is that thinner layers, generally between 25, and 50 µm, tend to enhance the mechanical strength of dental resins [18,21-23]. Increased flexural strength, and hardness at these finer layer settings are commonly reported for denture base resins, and interim crowns [5,18]. The improved mechanical properties can be attributed to more effective layer-to-layer bonding, and a higher degree of polymer conversion, which decreases internal porosity, and micro-defects that serve as stress concentrators [20]. This effect aligns with foundational additive manufacturing principles where thinner layers yield more homogenous, and tightly bound printed structures [2].

However, this relationship is not consistently linear. Certain composite materials, including CF/PLA, and shape memory resins, exhibit optimal mechanical properties at relatively thicker layers (approximately 0.6-0.7 mm), indicating that material composi-tion, and resin chemistry influence how layer thickness affects strength [22,19]. These observations suggest that mechanical performance is determined by the interplay between layer thickness, resin formulation, and the specific 3D printing technology used. Hence, material-specific optimization protocols are needed rather than a one-size-fits-all approach.

Surface Roughness, and Microbial Adhesion

Surface quality affects esthetic outcomes, and biological responses such as plaque accumulation, and secondary caries risk [21]. Thinner layers produce smoother surfaces due to the finer step increments in each printed layer, reducing microscopic ridges, and valleys where bacteria can adhere [25,9]. Moreover, surface roughness influences patient comfort, and staining susceptibility, making it a crucial parameter in material selection, and printing settings [39,54,58].

Optical Properties, and Esthetics

Esthetics remains a central consideration in prosthetic dentistry, with optical properties such as translucency, color stability, and surface gloss playing key roles. The review findings suggest that thinner printing layers enhance optical uniformity by minimizing light scattering, and creating smoother surfaces, resulting in more natural-looking restorations [21]. These effects are particularly important for anterior restorations, where seamless integration with the surrounding dentition is critical. Nev-ertheless, post-curing protocols, and resin pigmentation also impact final esthetic outcomes, interacting with layer thickness in complex ways [26].

Limitations

This review has several limitations. The included studies were highly heterogeneous in printer types, materials, layer thicknesses, testing protocols, and post-processing methods, limiting generalizability. Moreover, the predominance of in-vitro studies restricts direct clinical translation, as factors such as saliva, masticatory forces, and thermal cycling were not fully simulated. Finally, publication bias may exist, as studies with significant findings tend to be reported more frequently. Future clinical studies, and standardized testing protocols are needed to validate the laboratory findings, and optimize printing parameters for clinical use.

Future Directions

Given the rapidly evolving nature of 3D printing technology, and materials, further standardized research is essential to develop comprehensive guidelines. Future studies should employ consistent testing methodologies, including standardized specimen designs, post-processing protocols, and clinically relevant aging simulations. Additionally, in vivo studies evaluating the long-term clinical performance of 3D-printed restorations fabricated with varying layer thicknesses are necessary to translate in-vitro findings into practice.

Trade-offs, and Clinical Implications

Despite the advantages of thinner layers in accuracy, strength, and esthetics, thicker layers offer practical benefits including faster print times, and reduced material consumption, which are important in busy dental laboratories, and clinics [2,3]. These trade-offs must be balanced according to the clinical situation, with provisional restorations potentially favoring speed over optimal detail, while definitive prostheses may prioritize mechanical, and esthetic excellence. Furthermore, layer thickness does not act in isolation, but is interdependent with build orientation, printer type (SLA, DLP, LCD), resin composition, and environmental factors. This complexity demands an integrated approach to protocol development, incorporating manufacture specifications, and empirical data to tailor printing parameters for each application [27].

Conclusion

Layer thickness critically affects the mechanical, dimensional, and surface properties of 3D-printed dental materials. Thinner layers generally improve surface smoothness, and certain mechanical properties, while thicker layers may reduce printing time, and occasionally enhance strength depending on the material. Optimal outcomes require balancing layer thickness with other printing parameters, such as build angle, and post-curing. Although in-vitro evidence is promising, further clinical studies are needed to validate these findings, and establish standardized guidelines for layer thickness selection.

Conflict of Interest

The authors declared no potential conflicts of interest with respect to the research, authorship and/or publication of this article.

Financial Disclosure

None.

Acknowledgment

None.

Author’s Contribution

All authors read, and approved the final manuscript.

References

  1. Witkowski S. CAD/CAM in dental technology. Quintessence Dent Technol. 2005;28:169-84.
  2. Revilla-León M, Özcan M. Additive manufacturing technologies used for processing polymers: Current status, and potential application in prosthetic dentistry. J Prosthodont. 2019;28:146-58.
  3. Jawahar A, Maragathavalli G. Applications of 3D printing in dentistry-a review. J Pharm Sci Res. 2019;11:1670-5.
  4. Konidena A. 3D printing: Future of dentistry? J Indian Acad Oral Med Radiol. 2016;28:109-10.
  5. Alshamrani AA, Raju R, Ellakwa A. Effect of printing layer thickness, and postprinting conditions on the flexural strength, and hardness of a 3D-printed resin. Biomed Res Int. 2022;2022:8353137.
  6. Liu Q, Leu MC, Schmitt SM. Rapid prototyping in dentistry: Technology, and application. Int J Adv Manuf Technol. 2006;29:317-35.
  7. Barazanchi A, Li KC, Al-Amleh B, Lyons K, Waddell JN. Additive technology: Update on current materials, and applications in dentistry. J Prosthodont. 2017;26:156-63
  8. Turkyilmaz I, Wilkins GN. 3D printing in dentistry-exploring the new horizons. J Dent Sci. 2021;16:1037-8.
  9. Shim JS, Kim JE, Jeong SH, Choi YJ, Ryu JJ. Printing accuracy, mechanical properties, surface characteristics, and microbial adhesion of 3D-printed resins with various printing orientations. J Prosthet Dent. 2020;124:468-75.
  10. Simoneti DM, Pereira-Cenci T, Dos Santos MBF. Comparison of material properties, and biofilm formation in interim single crowns obtained by 3D printing, and conventional methods. J Prosthet Dent. 2020.
  11. Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent. 2016;115:760-7.
  12. Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-coverage dental restorations using stereolithography technology. Int J Prosthodont. 2016;29:503-10.
  13. Yoo SY, Kim SK, Heo SJ, Koak JY, Kim JG. Dimensional accuracy of dental models for three-unit prostheses fabricated by various 3D printing technologies. Materials. 2021;14:1550.
  14. Ajayi OK, Du S, Odemokoya TA, Bayonle O. Influence of printing speed, layer thickness, and infill percentage on the mechanical properties of 3D-printed PLA filament for prototyping. Niger J Technol Dev. 2025;22(3):1-2.
  15. Favero CS, English JD, Cozad BE, Wirthlin JO, Short MM, Kasper FK. Effect of print layer height, and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofacial Orthop. 2017;152:557-65.
  16. Ko J, Bloomstein RD, Briss D, Holland JN, Morsy HM, Kasper FK, Huang W. Effect of build angle, and layer height on the accuracy of 3-dimensional printed dental models. Am J Orthod Dentofacial Orthop. 2021;160:451-8.
  17. Yuan J, Tian J, Chen C, Chen G. Experimental investigation of color reproduction quality of color 3D printing based on colored layer features. Molecules. 2020;25:2909.
  18. ElShebiny T, Matthaios S, Menezes LM, Tsolakis IA, Palomo JM. Effect of printing technology, layer height, and orientation on assessment of 3D-printed models. J World Fed Orthod. 2024;13:169-74.
  19. Song S, Zhang J, Liu M, Li F, Bai S. Effect of build orientation, and layer thickness on manufacturing accuracy, printing time, and material consumption of 3D printed complete denture bases. J Dent. 2023;130:104435.
  20. Reymus M, Lümkemann N, Stawarczyk B. 3D-printed material for temporary restorations: Impact of print layer thickness, and post-curing method on degree of conversion. Int J Comput Dent. 2019;22:231-7.
  21. Lee EH, Ahn JS, Lim YJ, Kwon HB, Kim MJ. Effect of layer thickness, and printing orientation on the color stability, and stainability of a 3D-printed resin material. J Prosthet Dent. 2022;127:784.e1-6.
  22. Borella PS, Alvares LA, Ribeiro MT, Moura GF, Soares CJ, Zancopé K, Mendonça G, Rodrigues FP, das Neves FD. Physical, and mechanical properties of four 3D-printed resins at two different thick layers: An in-vitro comparative study. Dent Mater. 2023;39:686-92.
  23. Jang G, Kim SK, Heo SJ, Koak JY. Fit analysis of stereolithography-manufactured three-unit resin prosthesis with different 3D-printing layer thicknesses. J Prosthet Dent. 2024;131:301-12.
  24. Loflin WA, English JD, Borders C, Harris LM, Moon A, Holland JN, Kasper FK. Effect of print layer height on the assessment of 3D-printed models. Am J Orthod Dentofac Orthop. 2019;156:283-9.
  25. Lee WJ, Jo YH, Yilmaz B, Yoon HI. Effect of build angle, resin layer thickness, and viscosity on the surface properties, and microbial adhesion of denture bases manufactured using digital light processing. J Dent. 2023;137:104608.
  26. Tahayeri A, Morgan M, Fugolin AP, Bompolaki D, Athirasala A, Pfeifer CS, Ferracane JL, Bertassoni LE. 3D printed versus conventionally cured provisional crown, and bridge dental materials. Dent Mater. 2018;34:192-200.
  27. Osman RB, Alharbi N, Wismeijer D. Build angle: Does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology? Int J Prosthodont. 2017;30:182-8.
  28. Li SY, Zhou M, Lai YX, Geng YM, Cao SS, Chen XM. Biological evaluation of three-dimensional printed co-poly lactic acid/glycolic acid/tri-calcium phosphate scaffold for bone reconstruction. Chin J Stomatol. 2016;51:661-6.
  29. Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital, and conventional impression techniques, and workflow. Clin Oral Investig. 2013;17:1759-64.
  30. Donovan TE. Factors essential for successful all-ceramic restorations. J Am Dent Assoc. 2008;139 Suppl:S14-8.
  31. AlRumaih HS, Gad MM. The effect of 3D printing layer thickness, and post-polymerization time on the flexural strength, and hardness of denture base resins. Prosthesis. 2024;6:970-8.
  32. Ayrilmis N. Effect of layer thickness on surface properties of 3D printed materials produced from wood flour/PLA filament. Polym Test. 2018;71:163-6.
  33. Vinoth Babu N, Venkateshwaran N, Rajini N, Ismail SO, Mohammad F, Al-Lohedan HA, Suchart S. Influence of slicing parameters on surface quality, and mechanical properties of 3D-printed CF/PLA composites fabricated by FDM technique. Mater Technol. 2022;37:1008-25.
  34. Bakardzhiev V, Sabev S, Kasabov P. Research on the impact of extrusion temperature, printing speed, and layer thickness in 3D printing using material deposition technology. AIP Conf Proc. 2024;2980:060004.
  35. Çakmak G, Cuellar AR, Donmez MB, Abou-Ayash S, Lu WE, Schimmel M, Yilmaz B. Effect of printing layer thickness on the trueness of 3-unit interim fixed partial dentures. J Prosthet Dent. 2024;131:718-25.
  36. Çakmak G, Cuellar AR, Donmez MB, Schimmel M, Abou-Ayash S, Lu WE, Yilmaz B. Effect of printing layer thickness on the trueness, and margin quality of 3D-printed interim dental crowns. Appl Sci. 2021;11:9246.
  37. Corbani K, Hardan L, Skienhe H, Özcan M, Alharbi N, Salameh Z. Effect of material thickness on the fracture resistance, and failure pattern of 3D-printed composite crowns. Int J Comput Dent. 2020;23:225-33.
  38. Cremonini F, Cappelletti M, Brucculeri L, Olivero V, Lombardo L. An in-vitro comparison study regarding retention force expressed by thermoformed aligners, and 3D-printed aligners with different thickness, and design. Appl Sci. 2025;15:1345.
  39. de Gois Moreira FG, Bezerra MG, de Miranda LM, da Silva SE, de Andrade Dantas EL, de Sousa FB, Özcan M, e Souza RO. Influence of build angle, printing layer thickness, and aging on the flexural strength, precision, roughness, and porosity analysis of a printed resin for provisional restorations. Odontology. 2025;113:1-5.
  40. Türksayar AA, Diker B. Effect of layer thickness, and polishing on wear resistance of additively manufactured occlusal splints. J Dent. 2024;146:105101.
  41. Espinar C, Della Bona A, Tejada-Casado M, Pulgar R, Perez MM. Optical behavior of 3D-printed dental restorative resins: Influence of thickness, and printing angle. Dent Mater. 2023;39:894-902.
  42. Farkas AZ, Galatanu SV, Nagib R. The influence of printing layer thickness, and orientation on the mechanical properties of DLP 3D-printed dental resin. Polymers. 2023;15:1113.
  43. Farzadi A, Solati-Hashjin M, Asadi-Eydivand M, Abu Osman NA. Effect of layer thickness, and printing orientation on mechanical properties, and dimensional accuracy of 3D printed porous samples for bone tissue engineering. PLoS One. 2014;9:e108252.
  44. Fouda S, Ji W, Gad MM, AlGhamdi MA, Rohr N. Flexural strength, and surface properties of 3D-printed denture base resins-effect of build angle, layer thickness, and aging. Materials. 2025;18:913.
  45. Gad MM, Alzaki FA, Abuwarwar FA, Alhammad A, Al Hussain M, Khan SQ, Nassar EA, Ayad NM. Impact of printing layer thickness on the flexural strength of nanocomposite 3D printed resins: An in-vitro comparative study. Saudi Dent J. 2024;36:1307-12.
  46. García-Gil I, Rodríguez Alonso V, Tobar Arribas C, Mosaddad SA, Peláez J, Suárez MJ. Dental casts for fixed dental prostheses printed with SLA technology: Influence of external shell thickness, and printing orientation. Materials. 2025;18:2246.
  47. Grymak A, Badarneh A, Ma S, Choi JJ. Effect of various printing parameters on the accuracy (trueness, and precision) of 3D-printed partial denture framework. J Mech Behav Biomed Mater. 2023;140:105688.
  48. Hasanzade M, Yaghoobi N, Nematollahi P, Ghazanfari R. Comparison of the marginal, and internal fit of PMMA interim crowns printed with different layer thicknesses in 3D-printing technique. Clin Exp Dent Res. 2023;9(5):832-9.
  49. Iyibilgin O. Investigation of the effect of layer thickness on the mechanical properties of 316L austenitic stainless steel in additive manufacturing with metal filament. Appl Sci. 2025;15:2584.
  50. Khalil AS, Zaher AR. Effect of printing orientation, and resin thickness on flexural strength of direct 3D-printed aligners. BMC Oral Health. 2025;25:238.
  51. Kul E, Ostovar S, Kahraman S, Yanıkoğlu N, Yeşildal F. The effect of post-polymerization methods, and varying thicknesses on colour stability, and flexural strength of denture base polymers produced with stereolithography (SLA) technique. BMC Oral Health. 2025;25:488.
  52. Li P, Fernandez PK, Spintzyk S. Effects of layer thickness, and build angle on the microbial adhesion of denture base polymers manufactured by digital light processing. J Prosthodont Res. 2023;67:562-7.
  53. Liu Y, Bai W, Cheng X, Tian J, Wei D, Sun Y, Di P. Effects of printing layer thickness on mechanical properties of 3D-printed custom trays. J Prosthet Dent. 2021;126(5):671.e1.
  54. Mahajan S, Gopan G, Bhatawadekar SD, Khalikar S, Mahale K, Rajguru V. Effect of printing layer thickness on the color stability, and surface roughness of three-dimensional printed resin material immersed in different aging media: An in-vitro Int J Prosthodont Restor Dent. 2025;15(1):36-40.
  55. Mushtaq RT, Iqbal A, Wang Y, Rehman M, Petra MI. Investigation, and optimization of effects of 3D printer process parameters on performance parameters. Materials. 2023;16(9):3392.
  56. Park SY, Choi SH, Yu HS, Kim SJ, Kim H, Kim KB, Cha JY. Comparison of translucency, thickness, and gap width of thermoformed, and 3D-printed clear aligners using micro-CT, and spectrophotometer. Sci Rep. 2023;13(1):10921.
  57. Reymus M, Lümkemann N, Stawarczyk B. 3D-printed material for temporary restorations: Impact of print layer thickness, and post-curing method on degree of conversion. Int J Comput Dent. 2019;22(3):231-7.
  58. Sasany R, Jamjoon FZ, Kendirci MY, Yilmaz B. Effect of printing layer thickness on optical properties, and surface roughness of 3D-printed resins: An in-vitro Int J Prosthodont. 2024;37(7):165-73.
  59. Shergill K, Chen Y, Bull S. What controls layer thickness effects on the mechanical properties of additive manufactured polymers. Surf Coat Technol. 2023;475:130131.
  60. Sousa AM, Pinho AC, Piedade AP. Mechanical properties of 3D printed mouthguards: Influence of layer height, and device thickness. Mater Des. 2021;203:109624.
  61. Wu C, Mangal U, Bai N, Kim H, Hwang G, Cha JY, Lee KJ, Kwon JS, Choi SH. Effects of printing layer thickness, and build orientation on the mechanical properties, and color stability of 3D-printed clear aligners. Angle Orthod. 2025;95:355-61.
  62. Yang MS, Kim SK, Heo SJ, Koak JY, Park JM. Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations, and layer thicknesses. J Adv Prosthodont. 2022;14:250-7.
  63. Yilmaz B, Donmez MB, Kahveci Ç, Cuellar AR, de Paula MS, Schimmel M, Abou-Ayash S, Çakmak G. Effect of printing layer thickness on the trueness, and fit of additively manufactured removable dies. J Prosthet Dent. 2022;128:1318.e1.
  64. Yılmaz D, Sabatini GP, Kahveci Ç, Yoon HI, Yilmaz B, Çakmak G, Dönmez MB. Effect of material thickness, and coffee thermocycling on the color stability, and translucency of additively, and subtractively manufactured resin-based materials for definitive restorations. Int J Prosthodont. 2024;37:143-50.
  65. You SM, You SG, Kang SY, Bae SY, Kim JH. Evaluation of the accuracy (trueness, and precision) of a maxillary trial denture according to the layer thickness: An in-vitro J Prosthet Dent. 2021;125:139-45.
  66. Zhang ZC, Li PL, Chu FT, Shen G. Influence of the three-dimensional printing technique, and printing layer thickness on model accuracy. J Orofac Orthop. 2019;80:194-204.

Sandy Hazko1, Louis Hardan2,3, Naji Kharouf4,5, Carlos Enrique Cuevas-Suárez6*, Karim Corbani2,7, Hani Tohme3,8, Abigailt Flores-Ledesma9, Monika Lukomska-Szymanska10, Nicolas Nassar3,11,12, Rim Bourgi2,4,13*

1Surgical Department, Medizinische Hochschule Hannover, 30625 Hannover, Germany
2Department of Restorative, and Esthetic Dentistry, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
3Department of Digital Dentistry, AI, and Evolving Technologies, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
4Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
5Department of Endodontics, and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
6Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca 42160, Mexico
7Laser Unit, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
8Department of Removable Prosthodontics, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
9Dental Materials, and Biomaterials Laboratory, Faculty of Stomatology, Meritorious Autonomous University of Puebla, Puebla 72000, Mexico
10Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
11Craniofacial Research Laboratory, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
12Department of Orthodontics, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
13Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, Beirut 115020, Lebanon

*Correspondence author:Rim Bourgi, Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, and Lebanon, and Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, 115020 Beirut, Lebanon, and Department of Restorative, and Esthetic Dentistry, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon;
Email: [email protected]; [email protected]

Sandy Hazko1, Louis Hardan2,3, Naji Kharouf4,5, Carlos Enrique Cuevas-Suárez6*, Karim Corbani2,7, Hani Tohme3,8, Abigailt Flores-Ledesma9, Monika Lukomska-Szymanska10, Nicolas Nassar3,11,12, Rim Bourgi2,4,13*

1Surgical Department, Medizinische Hochschule Hannover, 30625 Hannover, Germany
2Department of Restorative, and Esthetic Dentistry, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
3Department of Digital Dentistry, AI, and Evolving Technologies, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
4Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
5Department of Endodontics, and Conservative Dentistry, Faculty of Dental Medicine, University of Strasbourg, 67000 Strasbourg, France
6Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca 42160, Mexico
7Laser Unit, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
8Department of Removable Prosthodontics, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
9Dental Materials, and Biomaterials Laboratory, Faculty of Stomatology, Meritorious Autonomous University of Puebla, Puebla 72000, Mexico
10Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
11Craniofacial Research Laboratory, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
12Department of Orthodontics, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
13Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, Beirut 115020, Lebanon

*Correspondence author:Rim Bourgi, Department of Biomaterials, and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, and Lebanon, and Department of Restorative Sciences, Faculty of Dentistry, Beirut Arab University, 115020 Beirut, Lebanon, and Department of Restorative, and Esthetic Dentistry, School of Dentistry, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon;
Email: [email protected]; [email protected]

Copyright© 2025 by Hazko S, et al. All rights reserved. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Citation: Hazko S, et al. The Impact of Layer Thickness on Key Parameters Affecting 3D-Printed Dental Materials: A Systematic Review. Jour Clin Med Res. 2025;6(3):1-21.